Schematics
Residential
| Application | Model | Major Components | ||
|---|---|---|---|---|
| Whole-house collection for irrigation - 70 psig or greater city water pressure | RUSOPH | Underground Plastic Tank - Submersible Pump - No Filtration- With PRV Standby Connection - Hydro Tank Also see tank installation detail below |
DWG | |
| Whole house collection for irrigation - low city water pressure | RUSOSH | Underground Plastic Tank - Submersible Pump - No Filtration- With Standby Connection - Hydro Tank Also see tank installation detail below |
DWG | |
| Raised beds, collection from a greenhouse or garage | RDSOPH | Above Ground Plastic Tank - Submersible Pump - No Filtration - With Standby Connection - Hydro Tank |
DWG | |
| Whole-house collection for toilet flushing | RUSUPH | Underground Plastic Tank - Submersible Pump - Sediment & UV Filtration- With Standby Connection - Hydro Tank Also see tank installation detail below |
DWG | |
| Whole-house collection for potable uses, with underground tank | RUSDPH | Underground Plastic Tank - Submersible Filtration- With Standby Connection - Hydro Tank Also see tank installation detail below |
DWG | |
| Whole-house collection for potable uses, with above-ground tank | RDSDPH | Above Ground Plastic Tank - Submersible Pump
Filtration- With Standby Connection - Hydro Tank | DWG | |
| Gray Water Reuse for irrigation | AUSOPH | Aqualoop - UG Tank - Subm Pump - No Filter - Hydro Tank - PRV Standby Connection - Hydro Tank |
DWG | |
| Whole-house collection, with pumped stormwater overflow. Useful when tank location doesn't allow gravity overflow. | RSSOSX | Stormchamber tank (with pond liner) - Submersible Pump, No filter - No Hydro Tank - Solenoid Valve Standby | DWG |
Commercial
| Application | Model | Major Components | ||
|---|---|---|---|---|
| Potable applications, with above-ground tank | RDCDPH | Above Ground Plastic Tank - Surface pumps on pump skid - First-Flush, Sediment, Carbon & UV Filtration- With Standby Connection - Hydro Tank |
DWG | |
| Nonpotable applications, but with first flush for emergency potable use, with above-ground tank. With standby connection | RDCOPH | Above Ground Plastic Tank - Surface pumps on pump skid - First-Flush, No filtration - With Standby Connection - Hydro Tank | DWG | |
| Nonpotable applications, but with first flush for emergency potable use, with above-ground tank. No standby connection | RDCOXH | Above Ground Plastic Tank - Surface pumps on pump skid - First-Flush, No filtration - No Standby Connection - Hydro Tank |
DWG | |
| < 5 Story Building Toilet flushing & Cooling Tower Makeup >100 gpm (above ground tank) | RQCBPH | Above Ground Metal Tank - Submersible Pump - UV Treatment - Day Tank - CCES Building Pumpa - *PRV* Standby Connection - Hydro Tank |
DWG | |
| < 5 Story Building Toilet flushing & Cooling Tower Makeup >100 gpm (above ground tank) | RQCBSH | Above Ground Metal Tank - Submersible Pump - UV Treatment - Day Tank - CCES Building Pump - *ELECTRIC VALVE* Standby Connection - Hydro Tank |
DWG | |
| < 5 Story Building Toilet flushing & Cooling Tower Makeup >100 gpm (below ground tank) | RUSBPH | Ground Metal Tank - Submersible Pump - UV Treatment - Day Tank - CCES Building Pump - *ELECTRIC VALVE* Standby Connection - Hydro Tank |
DWG | |
| < 5 Story Building Toilet flushing & Cooling Tower Makeup <100 gpm (above ground tank) | RQCUPH | Above Ground Metal Tank -Treatment - CCES Building Pump - PRV Standby Connection - Hydro Tank |
DWG | |
| > 5 Story Building Toilet flushing & Cooling Tower Makeup <100 gpm (above ground tank) | RQCBBH | Above Ground Metal Tank -Treatment - CCES Building Pump - Buffer Tank Fill Standby Connection - Hydro Tank |
DWG | |
| Rainwater + Groundwater, Toilet flushing & Cooling Tower Makeup (above ground tank), City Water Pressure < Building Pump Pressure | RUCBIH | Underground Tank - Groundwater Sump and Treatment Skid - Rainwater Treatment - Above Ground Plastic Tank - CCES Building Pump - Solenoid Connection to Building Pump Inlet |
DWG | |
| Concrete tank built into parking deck, high ratio of collection surface vs. usage, toilet flushing use included. | RHSUCH | Underground Concrete - Sub Pump - Sed and UV - Hydro Tank - Tank Fill Standby Connection |
DWG | |
| Underground fiberglass tank, pump installed in sub-basement, toilet flushing use included | RCCUPH | Underground Fiberglass Tank - CCES Pump - SC Sed and UV - Hydro Tank - Direct Standby Connection |
DWG | |
| Stormwater & rainwater collection. Suitable for collection from roofs & driveways, used for irrigation. Pumped overflow option. | RSSOSX | Stormchamber tank (with pond liner) - Submersible Pump, No filter - No Hydro Tank - Solenoid Valve Standby Connection |
DWG |
Tank Installation Details
Commercial
Above Ground Plastic
Guide Specification
Guide specification for typical commercial system, including tanks, prefilters, pumps, controls, and final filters.Click here.